Glue valve dripping of dispensing machine
2020-04-27
This situation often occurs after the rubber valve is closed. Ninety-five per cent of these cases are due to the use of a small needle. Too small needle will affect the flow of liquid caused by back pressure, resulting in the formation of the valve closed shortly after the phenomenon of drip. Too small the needle will also affect the rubber valve began to use when the bubble action. This problem can be solved by simply replacing a larger needle. Tapered oblique needles produce the least back pressure and the smoothest liquid flow.★The air in the liquid will leak after the rubber valve is closed. It is best to exclude the air in the liquid in advance, or use glue that is not easy to contain bubbles. Or the first gel after the use of centrifugal defoaming.